Hand-held Electrode HOW 1
- Hand-held Electrode HOW 1
- for measurment of surface resistance according to valid standards of DIN, EN, IEC and ASTM
- comes with 2 conductive elastomer stripes at intervals of 10 mm and a total measuring length of 100 mm
- suitable to complete measurements at surfaces of flat specimes, for example varnished sampling plates or plastic foils
- no treatment of the specimes’ surface with conductive varnish necessary, no contermination of the specimes
- The guard ring can be used optional to bleed
fault currents on surfaces and to avoid errors in
measurements. - recommended measuring range:
1 V measuring voltage: 103 ohm to 1013 ohm
100 V measuring voltage: 105 ohm to 1013 ohm